Indoor Unit Faults
Error Code | Possible Cause |
---|---|
1 | Indoor unit room temperature sensor error |
2 | Indoor unit inlet pipe sensor error |
4 | Float switch error (optional) |
5 | Communication error between indoor unit and outdoor units |
6 | Indoor unit outlet pipe sensor error |
9 | Indoor unit EPROM error |
10 | Indoor unit BLDC motor fan lock |
12 | Indoor unit middle pipe sensor error |
Outdoor Unit Faults
Error Code | Possible Cause |
---|---|
21 | DC Peak (IPM Fault); Compressor DC voltage was too high |
22 | Current Transformed (CT2) error; Alternating current (AC) input too high |
23 | DC Link Low Volt |
25 | AC Low/High Volt |
26 | DC Comp Position Error (not providing rotation), Locking |
27 | PSC Fault; Current to inverter compressor between AC and DC converter circuit too high |
28 | Inverter compressor DC voltage is too high |
29 | Inverter compressor amperage is too high |
31 | Current-to-current transformer (CT) thermistor is too low |
32 | Inverter Compressor Discharge Pipe (D-Pipe) Overheat |
40 | CT Sensor Error; Thermistor is disconnected or shorted out |
41 | D-Pipe Sensor INV is disconnected or shorted out |
44 | Outdoor Air Sensor is disconnected or shorted out |
45 | Middle thermistor of outdoor unit condenser coil is disconnected or shorted out |
46 | Outdoor unit suction line thermistor is disconnected or shorted out |
48 | Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out |
53 | Communication failure from outdoor unit to indoor unit |
60 | Outdoor unit printed circuit board (PCB) EPROM check sum error |
61 | Outdoor unit condenser coil temperature is too high |
62 | Outdoor unit inverter compressor PCB heat sink temperature is too high |
63 | Condenser coil pipe thermistor temperature is too low |
65 | Heat sink thermistor has disconnected or has shorted out |
67 | Outdoor brushless direct current (BLDC) fan motor lock error |
LG Inverter Split AC Error Code List
c1 or ch1 | Indoor temperature sensor open or closed circuit |
c2 or ch2 | Outdoor temperature sensor open or closed circuit |
c4 or ch4 | Heat sink temperature sensor open or closed circuit |
c5 or ch5 | Communication indoor and outdoor units |
c6 or ch6 | Excessive current at inverter DC power circuit |
c7 or ch7 | Excessive compressor current |
c8 or ch8 | Indoor fan not rotating |
c9 or ch9 | Outdoor fan not rotating |
ca or ch10 | Faulty discharge thermistor |
cc | EEPROM error |
cd | Inverter module error |
po | System in power mode ( not a fault ) |
lo | System in test mode ( not a fault ) |